Solar PV System Design Professional — Illustrated Course
Six modules and eighteen illustrated lessons take you from the solar resource to a commissioned, maintained system. You size strings at the temperature extremes, choose inverters and DC/AC ratios, audit loads, size LFP and lead-acid battery banks, calculate voltage drop, fuses, SPDs and earthing, build a PVsyst-style loss budget, and compute LCOE and payback. A Casablanca rooftop and a Kenyan off-grid clinic are designed in full, with every number verified, and each lesson ends with a copy-ready tool, common mistakes, key takeaways and a self-check.
Course outline
Module 1: The solar resource and the site
Measure the sunshine a site really receives, read the sun path and shading, and run a professional site survey before any design starts.
- Irradiance, irradiation and peak sun hours (20 min)
- Sun path, tilt, azimuth and shading (20 min)
- The professional site survey and our two projects (20 min)
Module 2: Cells, modules and the I-V curve
Read a module datasheet like an engineer: the I-V curve, temperature and irradiance effects, bypass diodes, degradation and the certifications that matter.
- How a PV cell works: the I-V curve, Voc, Isc and MPP (20 min)
- Temperature, irradiance and real operating conditions (20 min)
- Shading, bypass diodes, degradation and certification (20 min)
Module 3: Grid-tied design: inverters and strings
Choose the right inverter architecture, size strings against voltage and current limits at both temperature extremes, and set a sound DC/AC ratio.
- Inverters: string, central, micro and hybrid (20 min)
- String sizing: voltage and current at the temperature extremes (22 min)
- DC/AC ratio, MPPT allocation and clipping (20 min)
Module 4: Off-grid and hybrid systems
Audit loads, size the battery bank for autonomy and depth of discharge, then size the array, controller and inverter-charger for a real off-grid clinic.
- The load audit: energy, peak power and surge (20 min)
- Battery bank sizing: autonomy, depth of discharge and efficiency (22 min)
- Off-grid architecture: array, charge controller and inverter-charger (22 min)
Module 5: Cables, protection and earthing
Size DC and AC cables for current and voltage drop, select fuses, isolators and RCDs, and protect the system against surges and earth faults.
- Cable sizing and voltage drop (20 min)
- Overcurrent protection, isolation and RCDs (22 min)
- Surge protection, earthing and the bill of materials (22 min)
Module 6: Yield, economics, commissioning and O&M
Predict energy with a transparent loss budget, prove the economics with LCOE and payback, then commission and maintain the system to standard.
- Energy yield and performance ratio (22 min)
- LCOE, payback and the business case (22 min)
- Commissioning, testing and O&M (22 min)
This course prepares for the Solar PV System Design Professional.