HPLC & Gas Chromatography Professional — Illustrated Course
Six modules and eighteen illustrated lessons written for working lab analysts: chromatography theory with every number calculated, separation modes, columns and UHPLC scaling, HPLC detectors and LC–MS, gas chromatography from carrier gas to headspace, system suitability and quantitation, data integrity, method development under ICH Q14, validation to ICH Q2(R2) and systematic troubleshooting. Each lesson has a real worked example and a copy-ready tool, including a method development worksheet, a system suitability sheet, a GC method sheet, a validation protocol skeleton and a troubleshooting log.
Course outline
Module 1: Chromatography Theory You Can Calculate
Retention, selectivity, efficiency and resolution: the four numbers behind every chromatogram, calculated from real peak data.
- Retention, Retention Factor and Selectivity (20 min)
- Column Efficiency, Plate Number and the van Deemter Equation (22 min)
- Resolution and the Purnell Equation (22 min)
Module 2: Separation Modes, Columns and Mobile Phases
Choose the right mode, column and mobile phase: reversed phase, pH and buffers, HILIC, ion exchange, SEC, UHPLC and gradient scaling.
- Reversed-Phase HPLC: Solvent Strength, pH and Buffers (22 min)
- Normal Phase, HILIC, Ion Exchange and Size Exclusion (20 min)
- Columns, Particles, UHPLC and Gradient Elution (24 min)
Module 3: HPLC Detectors and LC–MS
Choose and set up the right detector: UV/DAD and peak purity, fluorescence, RI, aerosol detectors, signal-to-noise and LC–MS.
- UV and Diode-Array Detection (20 min)
- Fluorescence, RI, Aerosol Detectors and Signal-to-Noise (20 min)
- LC–MS: Ionisation, Mass Analysers and Matrix Effects (24 min)
Module 4: Gas Chromatography in Practice
Carrier gases, capillary columns, inlets, temperature programmes, retention indices, detectors, headspace and derivatisation for GC.
- GC Fundamentals: Carrier Gases and Capillary Columns (22 min)
- GC Inlets, Temperature Programming and Retention Indices (24 min)
- GC Detectors, Headspace and Derivatisation (24 min)
Module 5: System Suitability, Quantitation and Data Integrity
Prove the system works, turn peak areas into reportable results, and integrate and report in a way that survives an inspection.
- System Suitability under USP <621> and Ph. Eur. 2.2.46 (24 min)
- Quantitation: External Standard, Internal Standard and Relative Response Factors (24 min)
- Integration, Data Review and Data Integrity (22 min)
Module 6: Method Development, Validation and Troubleshooting
Develop methods under ICH Q14, validate them to ICH Q2(R2) with calculated LOD and LOQ, and troubleshoot HPLC and GC systematically.
- Method Development under ICH Q14 (24 min)
- Validation to ICH Q2(R2): Specificity to LOD and LOQ (26 min)
- Troubleshooting HPLC and GC Systematically (26 min)
This course prepares for the HPLC & Gas Chromatography Professional.